Oil
Fired Boiler:
a) Fully wet-back design effectively absorbs radiant
heat into the water,
keeping tube ends and rear of boiler cooler than in dry back
design.
b) Three passes extract maximum usable heat from the fuel
c) Large, water-surrounded furnace tube assures complete
combustion and heat absorption without flame impingement.
Critical Pressure 10.54 Kg / Cm 2
| Parameters |
EPBL
I
|
EPBL
II
|
EPBL
III
|
EPBL
IV
|
EPBL
V
|
EPBL
VI
|
EPBL
VII
|
EPBL
VIII
|
EPBL
IX
|
EPBL
X
|
EPBL
XI
|
EPBL
XII
|
EPBL
XIII
|
EPBL
XIV
|
EPBL
XV
|
Steam
Output
( From & At 1000C ) (Tons/hr) |
0.5 |
0.75 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
5.0 |
6.0 |
8.0 |
10.0 |
12.0 |
14.0 |
| Overall
Length (m) |
3.80 |
4.00 |
4.20 |
4.30 |
4.60 |
5.10 |
5.25 |
5.54 |
5.85 |
6.20 |
7.00 |
8.00 |
8.80 |
9.50 |
9.50 |
| Overall
Width (m) |
2.20 |
2.20 |
2.35 |
2.45 |
2.55 |
2.70 |
2.75 |
2.77 |
2.93 |
3.12 |
3.20 |
3.30 |
3.60 |
3.90 |
4.00 |
| Overall
Height (m) |
3.00 |
3.10 |
3.20 |
3.37 |
3.50 |
3.67 |
3.75 |
3.80 |
4.00 |
4.10 |
4.20 |
4.35 |
4.50 |
5.00 |
5.20 |
| Steam
Branch (mm) |
40 |
50 |
50 |
65 |
80 |
100 |
100 |
100 |
100 |
150 |
200 |
200 |
200 |
200 |
200 |
| Water
Inlet (mm) |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
65 |
65 |
80 |
| Safety
Valve Size 2
Nos. (mm) |
20 |
20 |
25 |
25 |
40 |
40 |
40 |
40 |
50 |
50 |
65 |
80 |
100 |
100 |
125 |
| Blow
Down Size (mm) |
25 |
40 |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
50 |
50 |
65 |
65 |
80 |
| Flue
Gas Duct Size (mm) |
225 |
225 |
250 |
250 |
300 |
300 |
300 |
300 |
400 |
400 |
475 |
550 |
650 |
750 |
800 |
Coal
Fired Boiler:
Critical Pressure 10.54
Kg / Cm 2
| Parameters |
EPBL
I
|
EPBL
II
|
EPBL
III
|
EPBL
IV
|
EPBL
V
|
EPBL
VI
|
EPBL
VII
|
EPBL
VIII
|
EPBL
IX
|
EPBL
X
|
EPBL
XI
|
Steam
Output
( From & At 1000C ) (Tons/hr) |
0.5 |
0.75 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
5.0 |
6.0 |
| Overall
Length (m) |
2.60 |
3.10 |
3.20 |
4.70 |
5.30 |
5.60 |
6.00 |
6.00 |
6.10 |
6.30 |
6.40 |
| Overall
Width (m) |
2.20 |
2.40 |
2.40 |
2.50 |
2.60 |
3.00 |
3.50 |
4.00 |
4.20 |
4.40 |
4.60 |
| Overall
Height (m) |
2.50 |
2.60 |
2.80 |
3.00 |
3.20 |
3.50 |
3.70 |
3.90 |
4.10 |
4.50 |
4.70 |
| Steam
Branch (mm) |
40 |
50 |
50 |
65 |
80 |
100 |
100 |
100 |
100 |
150 |
200 |
| Water
Inlet (mm) |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
50 |
50 |
| Safety
Valve Size 2
Nos. (mm) |
20 |
20 |
25 |
25 |
40 |
40 |
40 |
40 |
50 |
50 |
65 |
| Blow
Down Size (mm) |
25 |
40 |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
50 |
| Flue
Gas Duct Size (mm) |
400 |
400 |
400 |
450 |
500 |
550 |
600 |
650 |
700 |
750 |
800 |
| I.
D. Fan Head (mm wg) |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
150 |
| F.
D. Fan Head (mm wg) |
- |
- |
- |
- |
- |
- |
75 |
75 |
75 |
75 |
80 |
| No.
of Flue Passes |
2 |
2 |
2 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
Design and dimensions subject to change without notice
|